HOME | INDUSTRIAL | STATIC | PLATING | NUCLEAR | CONTACT US
 
Nuclear Products
Nuclear Products - Counting Systems
PNC-1G : Para Nuclear Counter (GM Tube Based)
Download Pdf

Para Nuclear Counter, Model PNC-1G is a micro controller based, economical, stand alone, portable mains operated instrument for Nuclear Counting application. It is a versatile instrument can be programmed as Preset Timer.

Model PNC-1G uses GM tube as nuclear radiation detector. Necessary electronics & high voltage supply are housed in the equipment. Coaxial cable with UHF connector connects the GM tube to Model PNC-1G.PNC-1G can store 1000 readings in a non-volatile memory. These readings can be downloaded to PC via USB interface. These readings can also be scanned on LCD display after the counting experiment.

PNC-1G is also equipped with special Plateau Mode. In this mode, HV is automatically increased in steps of 50 Volts. For each HV setting, average counts reading is stored in the memory. These readings are recalled to view them on LCD. User can transfer these readings to PC using data transfer software which will generate plateau graph indicating Plateau slope.

PNC-1G is ideally suited for Nuclear Experiments carried out in Universities and colleges. It is also useful for (Gamma / Beta) radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, nuclear medicine centers etc. End window GM tube Model 712 or equivalent can be supplied along with a planchet holder as an accessory for Model PNC-1G. Any other End Window GM tube can also be supplied as an option. Appropriate GM tube is selected, depending upon the application.

Lead Shield with door assembly is available as optional accessory for low level counting applications. It houses the GM Tube and planchet holder. Shield dimensions are development on the selected GM Tube.

Specifications :

PNC-1G with Planchet Holder Assembly

Counter
Electronics : All solid state, Micro-Controller based design
Preset Time :

Time settable between 1 and 9999 seconds in Step of 1 second

or in HH:MM:SS format

No. of Runs : Settable between 1 to 1000
Display Counts : Counts: 999999
Time : 9999 or in HH:MM:SS format
Runs : 1000
HV Supply : Adjustable to 1500V (±5V), settable through feather touch keypad on front panel.
Data Storage : Store and recall facility for counts data up to 1000 readings and for the plateau readings
User Interface : 4 keys keypad with 16x2 line LCD for displaying Key function
Data Transfer : To PC USB Port
GM Detector
(Select from following, standard price includes Model 712, other GM tube(s) at extra cost)
Model 712 (gamma sensitivity : 18 CPS/mR/Hr) mounted on Acrylic Planchet Holder
Model 7224 / 72314 mounted Acrylic Planchet Holder ( for beta measurement application)
Any other GM detector specified by user
Power Supply
240 V (±10%), 50 Hz Ac Mains, Through 12V battery charger
Mechanical
Dimensions : 200 L x 220 D x 70 H mm
Weight : Approximately 1 Kg
Accessories
  : Lead Shield with door arrangement for GM tube
Aluminum Absorber Kit
Radioactive Sources (on request, if available from BRIT, Mumbai)

Top

PNC-Alpha : Para Nuclear Counter (ZnS Tube Based)
Download Pdf

Para Alpha Counter Model PNC-Alpha is a micro-controller based, economical, stand alone instruments for Alpha counting applications. It works on an internally mounted 12V battery which is charged through mains operated charger ranging from 90-270 Volts AC Supply. Model PNC-Alpha, uses ZnS(Ag) alpha scintillator, is protected from stray light by a thin layer of aluminized myler sheet and is mounted on photo multiplier tube as nuclear radiation detector. Necessary electronics & high voltage supply are housed in the equipment. Coaxial cable with UHF connector connects the Alpha Detector to Model PNC-Alpha

PNC-Alpha can store 1000 readings in a non-volatile memory. These readings can be downloaded to PC via USB interface. These readings can also be scanned on LCD display after the counting experiment.

PNC-Alpha, is available in two types ‘Standard’ and ‘Low background’. Both type of units are except BACKGROUND Counts per Hour specification, rest all specifications of both types of units are same. Added advantage of this unit is, it calculates and displays the efficiency.

PNC-Alpha, is ideally suited for Nuclear Counting Experiments carried out in Universities and colleges. It is also useful for radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc.

A Drawer Assembly to hold 1" dia or 2" dia filter paper is supplied as standard accessory. The detector mounts upside down on the drawer assembly such that myler face of the detector is just 2 mm above the sample filter paper.

Specifications :

PNC-Alpha with Drawer Assembly

Counter
Electronics : All solid state, Micro-Controller based design
Preset Timer : Time settable between 1 and 9999 seconds in Step of 1 second
Number of Runs : Settable between 1 to 1000
Display : Counts : 999999
Time : 9999   or HH:MM:SS (RTC format)
Runs : 1000
HV Supply : Adjustable to 1500V by setting front panel mounted Trim pot
Data Storage : Store and recall facility for data up to 1000 readings
User Interface : 4 keys keypad with 16x2 line LCD for displaying Key function
Data Transfer : To PC USB Port
Alpha Detector
Alpha Scintillation ZnS(Ag), integral assembly with voltage divider on 2” dia PMT Approx Viewing area : 20 cm2, 2” dia circular scintillator ZnS Sheet placed on 2” PMT (Standard / Low background)
Detector Efficiency : Better than 25% with Am241 Source
Background Counts
– For Standard Alpha Counter : Less than 10 CPH
– For Low Background Alpha Counter : Less than 2-3 CPH
Drawer Assembly for 1” or 2”  filter paper measurement

Power Supply
Internally mounted 12V battery which is charged through main operated charger ranging from 90-270 Volts AC Supply
Mechanical
Dimension : 200 L x 220 D x 70 H mm
Weight : Approximately 1 Kg

Top

ALSCIN : Portable Alpha Scintillation Counter
Download Pdf

Para Alpha Scintillation Counter Model α-Scin is a micro-controller based, economical, stand alone, battery as well as mains operated instrument for Alpha Counting applications. α-Scin uses ZnS(Ag) alpha scintillator with aluminized mylar, mounted on photo multiplier tube as nuclear radiation detector. Necessary electronics and high voltage supply are housed in the equipment.

α-Scin is useful for Alpha counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc.

α-Scin is supplied with a drawer assembly which enables user to keep 1” or 2” dia samples under the scintillator.

α-Scin uses micro controller for counting, menu display and key board functions. Pulse processing electronics generates the TTL shaped pulses fed as input to the counter. Typical Alpha Counting efficiency is better than 22%.

α-Scin has 8 x 1 line LCD menu display with back-lit facility. Counts up to 999999 are displayed at the end of preset time. Timer can be set in Auto/Manual Mode. During Auto Mode,

α-Scin counts the pulses for 1 minute time interval and then displays on LCD. In Manual Mode of operation, Start/Stop Key sets the start and end of counting time. In Set Time Mode, preset time set by the user controls counter and after counting is over, counts will be displayed on LCD. Reset Key enables user to clear the counts taken in earlier run.

Specifications :

ALSCIN with Drawer Assembly

Counter
Micro Controller based counter
8 Character LCD display for counts
Counts capacity : 999999
Start/Stop/Reset Auto/Manual Switches
Operating Mode : Auto / Manual / Set Time
Preset Time : 1 Minute (Auto mode) or 1-9999 Minutes in Set Time Mode
Manual mode controlled by Start/Stop Switches
Battery Voltage indication, Power ON/OFF switch
HV settable between 100 to 1000V, internally
Calibration Source holder for 1” dia source
Enclosure : Aluminum table top enclosure
Alpha Detector
Alpha Scintillation ZnS(Ag), integral assembly with voltage divider on 2” dia PMT
Viewing area : 20 cm2 Approx., circular scintillator ZnS screen of 2” dia on 2” PMT
Detector Efficiency : > 22 %
Background – Less than 25 CPH
Drawer Assembly for 1" or 2" diameter filter paper measurement (optionally available)
Battery Charger (External)
240V AC mains input for 4 Ni-MH batteries
Mechanical
Dimensions (Overall) : 70 mm Dia x 280 mm Height
Weight : Approximately 3 Kg (Without drawer assembly 1.2 Kg)

Top

Automated Sample Changer - Alpha Counter
Download Pdf

Para Model ASC-05A / ASC-10A Automated Sample Changer - Alpha Counter is a versatile indigenously developed system for Alpha radiation counting of samples on 25 mm (1”) or 51 mm (2”) diameter filter papers or planchets.

Model ASC-05A / ASC-10A incorporates programmable sample positioning system and programmable Alpha Counting System. Once the system is programmed it can work On-line (PC connected) or Off-line (PC disconnected). Sample positioning/movement, system and counting parameters and report generation is programmed by user friendly menu based PC software. Alpha Counting System incorporates ZnS(Ag) Scintillation Detector **, programmable high voltage, preamplifier, spectroscopy amplifier, SCA/Counter/Timer programmable by PC. The front end electronics is specifically designed for achieving very low background counts.

The software provided with Automated Sample Changer – Alpha Counter assists user to set various Operating Parameters and Motion Control Parameters. Report is generated after completion of counting process with Sample ID, Counts, date, time, Operating parameters etc. in predefined formats. Reports can be saved in Text format and available for printing via USB port.

Model ASC-05A / ASC-10A is ideally suited for Health Physics labs, Environmental Survey labs, Nuclear Power Plants etc where large numbers of samples are handled for routine counting and records.

** Composite detector for separate Beta and Gamma gross counting application can also be supplied. Contact Factory for further details.

Specifications :

Alpha Detector
ZnS(Ag) Scintillator mounted on 2”x2” PMT for measurement of Alpha particles
Efficiency : 25% or better
Background : 2 – 3 counts per hour
Operating Parameters
Detector Operating Voltage : 0 to +1200 volts software programmable
Low Level Discriminator (LLD) : 0 to 5000mV software programmable
Upper Level Discriminator (ULD) : 0 to 5000 mV software programmable
Preset Timer : Software programmable in HH:MM:SS
Counter : 0 to 999999 maximum
No. of Repetitions : 1 to 10 maximum per sample
No. of Samples : 1 to 5 maximum for 51 mm (2”) dia Samples and
1 to 10 for 25 mm (1”) dia Samples
Next Sample travel time : 5 Secs
Sample Elevation time : 6 Secs
USB Interface : for PC/Laptop for Prgramming, Data Logging and Data Printing
Power Supply
240 V (+ 10%), 50 Hz Ac Mains, Single Phase
Mechanical
Dimensions : 495 D x 315 H x 325 W mm
Weight : Approximately 22 Kg

Top

Dual Channel Alpha Beta Counter
Download Pdf

Dual Channel Alpha Beta Counter model PNC-αβ is a micro-controller based, economical, stand alone, mains operated instrument for Dual Channel Nuclear Counting application for Alpha – Beta radiations. It is a versatile instrument designed to cater the counting application requirements.

Dual Channel Alpha Beta Counter Model PNC-αβ, uses Composite Detector (Plastic Scintillator and ZnS(Ag) Scintillator) for detection and measurement of alpha / beta radiation. High voltage required for the detector is generated in instrument. The load resistor for Photo Multiplier Tube (PMT) and the front end electronics for pulse processing circuits for the detector is housed in unit.

Dual Channel Alpha Beta Counter Model PNC-αβ, stores 1000 counts data (500 Alpha + 500 Beta) in a non-volatile memory. It generates formatted USB 2.0 output for transferring data to PC. USB male connector on the front panel is provided for transferring the data to PC. Support software for data transfer in Windows environment, is provided with system.

Model PNC-αβ is useful for radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, nuclear medicine centers etc.

A Drawer Assembly to hold 1" dia or 2" dia filter paper is supplied as standard accessory. The detector mounts upside down on the drawer assembly such that myler face of the detector is just 2 mm above the sample filter paper.

40mm thick Lead shield for detector can be supplied at extra cost (as shown in above photograph)

Specifications :

Dual Channel Alpha Beta with Drawer Assembly

Counter
Electronics : All solid state, Micro-Controller based design
Preset Time : Time settable between 1 and 9999 seconds in Step of 1 second
No. of Runs : Settable between 1 to 500
Display :

Counts : 999999

    Time : 9999 Seconds
    Runs : 500 Alpha + 500 Beta
HV Supply : Adjustable to 1200V by setting front panel mounted heliport with calibrated dial
Data Storage : Store and recall facility for data up to 1000 readings
User Interface : 4 keys keypad with 20x4 line LCD for displaying Key function
Data Transfer : To PC - via USB 2.0 through
    Windows based Data Transfer Software
Composite Detector
Radiation Detected: Alpha and Beta Particles
Detector: ZnS(Ag) adhered to 0.10” thick Plastic Scintillator mounted on 1.5” PMT.
Efficiency: (Alpha) 25% for Am241
               (Beta) better than 12% for Sr90 without lead shield
               better than 15% for Sr90 with 40mm thick lead shield
Background: 3 – 4 CPH for Alpha particles
                  3 – 4 CPM for Beta Particles (at 0-10 µR / Hr ambient background)
Crosstalk: Alpha to Beta <10%
              Beta to Alpha <1%
Power Supply
240 V (+ 10%), 50 Hz Ac Mains

Top

Dual Channel Alpha Beta Counter (EMI-EMC Compliant)
Download Pdf
EMI EMC Compliance Download Pdf
Environment Compliance Download Pdf

Dual Channel Alpha Beta Counter model PNC-αβ is a micro-controller based, economical, stand alone, mains operated instrument for Dual Channel Nuclear Counting application for Alpha – Beta radiations. It is a versatile instrument designed to cater the counting application requirements.

Dual Channel Alpha Beta Counter Model PNC-αβ, uses Composite Detector (Plastic Scintillator and ZnS(Ag) Scintillator) for detection and measurement of alpha / beta radiation. High voltage required for the detector is generated in instrument. The load resistor for Photo Multiplier Tube (PMT) and the front end electronics for pulse processing circuits for the detector is housed in unit.

Dual Channel Alpha Beta Counter Model PNC-αβ, stores 1000 counts (500 Alpha + 500 Beta) data in a non-volatile memory. It generates formatted USB 2.0 output for transferring data to PC. USB male connector on the front panel is provided for transferring the data to PC. Support software for data transfer in Windows environment, is provided with system.

Model PNC-αβ is useful for radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, nuclear medicine centers etc.

A Drawer Assembly to hold 1" dia or 2" dia filter paper is supplied as standard accessory. The detector mounts upside down on the drawer assembly such that myler face of the detector is just 2 mm above the sample filter paper.

40mm thick Lead shield for detector can be supplied at extra cost (as shown in above photograph)

Specifications :

Dual Channel Alpha Beta with Drawer Assembly

Counter
Electronics : All solid state, Micro-Controller based design
Preset Time : Time settable between 1 and 9999 seconds in Step of 1 second
No. of Runs : Settable between 1 to 500
Display :

Counts : 999999

    Time : 9999 Seconds
    Runs : 500 Alpha + 500 Beta
HV Supply : Adjustable to 1200V by setting front panel mounted heliport with calibrated dial
Data Storage : Store and recall facility for data up to 500 Alpha + 500 Beta readings
User Interface : 4 keys keypad with 20x4 line LCD for displaying Key function
Data Transfer : To PC - via USB 2.0 through Windows based Data Transfer Software
Composite Detector
Radiation Detected: Alpha and Beta Particles
Detector: ZnS(Ag) adhered to 0.10” thick Plastic Scintillator mounted on 1.5” PMT.
Efficiency: (Alpha) 25% for Am241
               (Beta) better than 12% for Sr90 without lead shield
               better than 15% for Sr90 with 40mm thick lead shield
Background: 3 – 4 CPH for Alpha particles
                  3 – 4 CPM for Beta Particles (at 0-10 µR / Hr ambient background)
Crosstalk: Alpha to Beta <10% and Beta to Alpha <1%
Power Supply
240 V (+ 10%), 50 Hz Ac Mains
Compliance
Operating Conditions: Temp +5oC to 55oC
                               Relative Humidity < 50% (50 to 95% Occasional)
EMI /EMC: IEC 61000-4-20 : 2010, IEC 61000-4-6 : 2013, IEC 61000-4-5 : 2005
               IEC 61000-4-2 : 2008, IEC 61000-4-8 : 2009
Environmental: IS 9000 (part 8) : 1981, IS 9000 (part 3) : 1977, IS 9000 (part 5) : 1981